SONNEN. Request a Quote
Quality · Certifications · Standards · Performance

Quality you can audit.

Certifications, the standards Sonnen helped draft, the methods the instruments comply with, and the performance data behind the ≥99.5% recovery figure.

Certified at every level.

CE

46 models CE-certified

Low Voltage Directive 2014/35/EU conformity across the analyzer line — all 36 current product lines plus legacy variants; the Kjeldahl line was additionally verified to the EMC Directive in 2012. Both certificates are published below.

ISO 9001:2015

Quality management system

ISO 9001:2015-certified design, manufacturing and service processes.

ISO 14001:2015

Environmental management

ISO 14001:2015-certified environmental management system across manufacturing operations.

ISO 45001:2018

Occupational health & safety

ISO 45001:2018-certified occupational health and safety management system.

National high-tech enterprise

R&D recognized

National High-Tech Enterprise certification (2017), six software copyright certificates (2016) and the Henan Province Science & Technology Achievement Certificate (2016).

Approved supplier

Listed, twice.

On the Approval Supplier List for China’s General Administration of Quality Supervision, Inspection and Quarantine in 2015 and again in 2017; supported by the National Innovation Fund.

Warranty, stated plainly.

Every Sonnen instrument carries a one-year warranty on the main unit as standard. Glassware and consumables are outside the warranty scope; glass components are inspected on delivery and, once confirmed intact on arrival, are likewise excluded.

Warranty service does not cover: units without valid proof of the warranty period; natural wear and ageing of consumables; damage caused by lightning or other power-system faults; damage caused by accident, disaster, war or other force majeure; self-modification, self-repair, or disassembly, modification or repair by third parties not designated by Sonnen; expiry of the warranty period; damage caused by use, maintenance or storage contrary to the product manual; or products not manufactured by Sonnen or without Sonnen identification.

Beyond the warranty year, spare parts are supplied for the lifetime of the instrument and software updates continue long-term — see the six written service commitments.

We don’t just follow standards — we draft them.

DrafterGB/T 22923-2008Automatic analyzers for determination of nitrogen, phosphorus and potassium in fertilizers.
DrafterJJF 109-2012Calibration Specification for Nitrogen Analyzers.
DrafterDB12/T 963-2020 · DB12/T 962-2020Tianjin local standards participation, 2020.
Methods & standards covered
GB/T22923-2008GB/T22923JJF 109-2012EN ISO 5983-2AOAC 2001:11ISO 20483ISO 8968-2IDF/FIL 20-2ISO 8968-3IDF/FIL 20-3ISO 8968-4IDF/FIL 20-4ISO 937AOAC 981.10ISO 1871ISO 3332ISO 3188ISO 5663/DIN 38409H11EN ISO 5664ISO 1656AOAC 2003.05AOAC 991.36ISO 1444:1996ISO 11085:2008GB/T 15674-1995ISO 6492:1999ISO 3947-1994ISO 6865ISO 16472AOAC 2002.04ISO 13906

The recovery-rate story.

≥99.5%Standard Kjeldahl recovery across the K-series line; the K18 reaches ≥99.8%.
99.1–99.2%Three-round result in the 2008 comparison by China National Fertilizer Testing Center — matching the imported reference point for point.
≤0.5%Repeatability, with 0.1–240 mg N measuring range and 3–8 minutes per sample.
2007

Nitric nitrogen, automated.

Sonnen developed the industry’s automatic determination module for nitric nitrogen — a determination most analyzers still require by hand.

2009

High-nitrogen recovery solved.

Sonnen resolved the long-standing problem of below-spec recovery on high-nitrogen chemical products.

Evidence you can download.

System certificates and sample factory reports are public below. Every instrument ships with its own per-unit test report — the samples here show the actual format and measured figures; request the file for your serial number and we send it.

System & product certificates
ISO 9001:2015 Quality management system certificate — No. 22824Q17191R1S, valid to 27 Nov 2027 View
ISO 14001:2015 Environmental management system certificate — No. 22824E13972R1S, valid to 27 Nov 2027 View
ISO 45001:2018 Occupational health & safety certificate — No. 22824S13563R0S, valid to 27 Nov 2027 View
CE · LVD Low Voltage Directive 2014/35/EU, EN 61010-1:2010 — UDEM certificate M.2025.206.C119651 covering 46 models (all 36 current product lines plus legacy variants), valid to 26 May 2030 PDF
CE · LVD+EMC Kjeldahl analyzer (azotometer) line — LVD 2006/95/EC & EMC 2004/108/EC verification, EN 61010-1 / EN 61326-1 — ECO certificate CE-12-1122-02, Nov 2012 (superseded directives; renewed under LVD 2014/35/EU above) View
Sample factory test reports (per-unit, issued before shipment)
K18 Factory test report — unit SS003116RW, May 2025: measured recovery ≥99.8%, repeatability ≤0.2% PDF
K1306 Factory test report — unit SS052113RL PDF
X08 Digester factory test report — unit SS082821RL PDF
GR08 Digester with fume removal — factory inspection report, unit SSGR0801024, October 2024 PDF
F22 Fiber analyzer factory test report — unit SS01203226, July 2026; re-set from the original digital record, English translation on page 2 PDF
Third-party calibration by national metrology institutes
K12 Calibration certificate 2017H00-10-480055 — SIMT (Shanghai Institute of Measurement and Testing Technology / National Center of Measurement and Testing for East China), Jul 2017, per JJF 1321-2011; measured indication error −1.15%, repeatability RSD 0.78% PDF
K06 Calibration certificate No. 201412009650 — NIMTT (National Institute of Measurement and Testing Technology, CNAS L0893), Dec 2014, unit SSK06C14090 View

Reports are issued in Chinese with stamped signatures — the format our domestic regulators audit. Need the report, CE file or calibration specification for another model? Contact our engineers. Calibration basis: JJF 109-2012, the national specification Sonnen helped draft.

Every instrument ships with its verification data.

Ask for the test reports.