T03 Titrator(Titration Unit)
+
  • T03 Titrator(Titration Unit)

T03 Titrator(Titration Unit)

Sonnen’s T03 titrator(titration unit) adopts high precision technical plunger pump, mouse automatically control adding liquid、titration、zero setting、LCD screen automatically show titration volume(the minimum unit is 0.01ml = 10μl), its accuracy could meet the demand of the most strict chemical laboratory’s titration test. Model:T03 Brand:Sonnen

Keywords: analytical instruments

details

Product Introduction

Sonnen’s T03 titrator(titration unit) adopts high precision technical plunger pump, mouse automatically control adding liquid、titration、zero setting、LCD screen automatically show titration volume(the minimum unit is 0.01ml = 10μl), its accuracy could meet the demand of the most strict chemical laboratory’s titration test.

Sonnen’s T03 titrator(titration unit) could combine with T11, “build blocks” mode realize potentiometric、PH、color and other various titration.

Product Features

Sonnen’s titrator adopts high precision technical plunger pump, made of German corrosion-resistant and ultra wear-resisting hard polymer material, non-shape-transformation, ensure precision of titration, long service life, LCD show digital clearly.

Automatically titration: easy operation、rational structure、mouse control titration;

Automatically initialization: automatically complete initialization refill with one click after titration;

Automatically return-to-zero: return to zero by key, then start next titration process;

Quantitative pipetting: automatically pipetting precisely as per the set volume; accurate to 0.01ml.(optional)

Product Function

With multiple functions as titration、pipetting、stir、data output. Completely abandon the tedious operation which by glass burette;

The part which touch reagent completely adopt anticorrosion material, nearly apply to all chemical lab(except hydrofluoric acid);

One mouse control all functions, control speed arbitrarily, operation simply;

The titration and pipetting precision to 10 microliter, which insure the result reliable;

LCD show data directly and clearly.

Technical Parameters:

mV/PH electrode interface for potential measurement

2-4

Temperature measuring interface for Pt1000

1

polarizedelectrode interface

2

Measuring range of mV

±2,000mV

Resolution

0.1℃

reference electrode interface

2

Resolution of mV

0.1mV

Error limit

0.2℃

Color sensor

16-bit and tri-primary color

Error limit of mV

0.2mV

Titration module interface

12

Dimentions of host

160 X 190 X 200mm

Measuring range of PH

0-14

Buret driver

1/60000step of the burette volume

Dimentions of titration module

200 X 190 X 320(mm)

Resolution of PH

0.01

Error limit

±0.2%(20ml) of the burette

Weight(standard configuration)

About 4.3kg

Error limit of PH

0.01

Filling time and discharge time

30 seconds at 100% filling rate

Note: All technical parameter are subject to change without notice.